Pasokan OEM/ODM 4 Core XLPE Insulated PVC Sheathed Unarmoured Power Cable/Fleksibel Flame Retardant Power Cable

Katrangan singkat:

Kabel digunakake kanggo sumber listrik ing sistem instalasi voltase kurang, Padha cocok kanggo instalasi ing njero ruangan lan njobo, ing saluran kabel, ing lemah, ing daya lan ngoper stasiun, distribusi energi lokal, tanduran industri, ngendi ora ana risiko mechanical. karusakan.

 

 

Penerimaan: OEM/ODM, Perdagangan, Grosir, Agensi Regional

Pembayaran: T/T, L/C, PayPal

Sampel Saham Gratis & Kasedhiya


Detail Produk

Tag produk

Kita duwe klompok efisiensi sing mumpuni kanggo menehi dhukungan sing apik kanggo klien kita.Kita biasane ngetutake prinsip berorientasi pelanggan, fokus rincian kanggo Pasokan OEM / ODM 4 Inti XLPE Insulated PVC Sheathed Unarmoured Power Cable / Fleksibel Flame Retardant Power Cable, Saiki, kita ngupayakake kerjasama sing luwih gedhe karo para panuku ing luar negeri sing ditemtokake kanthi bebarengan keuntungan.Mangga aran gratis kanggo hubungi kita kanggo rincian liyane.
Kita duwe klompok efisiensi sing mumpuni kanggo menehi dhukungan sing apik kanggo klien kita.Biasane kita tindakake prinsip customer-oriented, rincian-fokus kanggoKabel Tembaga China lan Tembaga Insulated PVC, Kanthi netepi prinsip "oriented manungsa, menang kanthi kualitas", perusahaan kita kanthi tulus nampani pedagang saka ing omah lan ing luar negeri kanggo ngunjungi kita, ngobrol bisnis karo kita lan bebarengan nggawe masa depan sing apik.

Aplikasi

Trunking kabel njero ruangan, njaba kanggo stasiun listrik, industri lan switchgear uga kanggo jaringan pasokan kutha, yen karusakan mekanis ora mungkin.

Konstruksi

avava

Karakteristik

Dirating voltase: 0.6/1kV

1. sak operasi normal kabel, suhu konduktor maksimum kudu 70 ℃ kanggo PVC jampel lan 90 ℃ kanggo XLPE jampel.
2. Suhu maksimum konduktor sajrone sirkuit cendhak (durasi maksimal ora ngluwihi 5 detik): Insulasi PVC - 160 ℃ kanggo bagean konduktor ≤300mm2, 140 ℃ kanggo bagean salib konduktor> 300mm2;Crosslinked PVC insulasi ing 250 ℃.
3. Nalika mbikak kabel, suhu sekitar ora bakal kurang saka 0 ℃, lan minimal allowable mlengkung radius minangka nderek:
Kabel inti tunggal: 20D tanpa lapis baja, 15D lapis baja
Kabel multi-inti: 15D kanggo unarmored, 12D kanggo armored
Where: D- diameteripun njaba kabel.
4. Kabel putus gaya:
Kabel inti aluminium: 40 × S (N)
Kabel inti tembaga: 70 × S (N)
Cathetan: S yaiku total area cross-sectional konduktor

Standar

IEC 60502-1, GB/T 12706.1

Paramèter

Kabel Daya Inti Tunggal

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

1×1.5

0.7

1.4

6

53

12.1

3.5

22

33

1×2.5

0.7

1.4

6

68

7.41

3.5

31

43

1×4

0.7

1.4

7

87

4.61

3.5

41

56

1×6

0.7

1.4

7

110

3.08

3.5

52

70

1×10

0.7

1.4

8

155

1.83

3.5

71

94

1×16

0.7

1.4

9

220

1.15

3.5

92

120

1×25

0.9

1.4

10

345

0.727

3.5

120

155

1×35

0.9

1.4

12

424

0.524

3.5

150

185

1×50

1

1.4

13

555

0.387

3.5

180

220

1×70

1.1

1.4

14

770

0.268

3.5

230

270

1×95

1.1

1.5

16

1040

0.193

3.5

285

320

1×120

1.2

1.5

18

1290

0.153

3.5

335

365

1×150

1.4

1.6

20

1590

0.124

3.5

385

410

1×185

1.6

1.6

22

1944

0,0991

3.5

450

465

1×240

1.7

1.7

25

2510

0,0754

3.5

535

540

1×300

1.8

1.8

27

3042

0,0601

3.5

620

610

1×400

2

1.9

31

3869

0.047

3.5

720

695

1×500

2.2

2.1

35

4910

0,0366

3.5

835

780

1×630

2.4

2.2

40

6220

0,0283

3.5

960

880

1×800

2.6

2.4

45

7870

0,0221

3.5

1110

970

1×1000

2.8

2.6

51

9804

0,0176

3.5

1230

1060

2 Kabel Daya Inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

2×2.5

0.7

1.8

11.8

151

7.41

3.5

26

35

2×4

0.7

1.8

12.7

198

4.61

3.5

34

45

2×6

0.7

1.8

13.7

250

3.08

3.5

43

57

2×10

0.7

1.8

15

374

1.83

3.5

60

77

2×16

0.7

1.8

17

518

1.15

3.5

83

105

2×25

0.9

1.8

20

772

0.727

3.5

105

125

2×35

0.9

1.8

22

1006

0.524

3.5

125

155

2×50

1

1.8

20

1365

0.387

3.5

160

185

2×70

1.1

1.8

21

1872

0.268

3.5

200

225

2×95

1.1

1.8

24

2475

0.193

3.5

245

270

2×120

1.2

1.8

27

3089

0.153

3.5

285

310

2×150

1.4

1.9

30

3834

0.124

3.5

325

345

3 Kabel Daya Inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

3×1.5

0.7

1.5

10

145

12.1

3.5

20

27

3×2.5

0.7

1.5

11

185

7.41

3.5

26

35

3×4

0.7

1.5

12

250

4.61

3.5

34

45

3×6

0.7

1.5

13

320

3.08

3.5

43

57

3×10

0.7

1.8

16

450

1.83

3.5

60

77

3×16

0.7

1.8

18

640

1.15

3.5

83

105

3×25

0.9

1.8

21

940

0.727

3.5

105

125

3×35

0.9

1.8

23

1260

0.524

3.5

125

155

3×50

1

1.8

23

1670

0.387

3.5

160

185

3×70

1.1

1.8

26

2280

0.268

3.5

200

225

3×95

1.1

1.9

30

3020

0.193

3.5

245

270

3×120

1.2

2

32

3790

0.153

3.5

285

310

3×150

1.4

2.2

37

4750

0.124

3.5

325

345

3×185

1.6

2.3

41

5654

0,0991

3.5

375

390

3×240

1.7

2.4

46

7243

0,0754

3.5

440

450

3×300

1.8

2.6

51

9465

0,0601

3.5

505

515

3×400

2

3

64

12066

0.047

3.5

570

575

4 Kabel Daya Inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

4×4

0.7

1.8

13

253

4.61

3.5

34

45

4×6

0.7

1.8

14

337

3.08

3.5

43

57

4×10

0.7

1.8

17

501

1.83

3.5

60

77

4×16

0.7

1.8

20

778

1.15

3.5

83

105

4×25

0.9

1.8

23

1160

0.727

3.5

105

125

4×35

0.9

1.8

25

1554

0.524

3.5

125

155

4×50

1

1.8

23

2148

0.387

3.5

160

185

4×70

1.1

1.8

27

2928

0.268

3.5

200

225

4×95

1.1

1.9

31

3854

0.193

3.5

245

270

4×120

1.2

2

33

4925

0.153

3.5

285

310

4×150

1.4

2.2

38

6238

0.124

3.5

325

345

4×185

1.6

2.3

42

7562

0,0991

3.5

375

390

4×240

1.7

2.5

47

9836

0,0754

3.5

440

450

4×300

1.8

2.6

52

12550

0,0601

3.5

505

515

4×400

2

3.1

66

15929

0.047

3.5

570

575

5 Kabel Daya Inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

5×4

0.7

1.8

14.5

349

4.61

3.5

34

45

5×6

0.7

1.8

15.8

460

3.08

3.5

43

57

5×10

0.7

1.8

19

699

1.83

3.5

60

77

5×16

0.7

1.8

22

1013

1.15

3.5

83

105

5×25

0.9

1.8

25

1566

0.727

3.5

105

125

5×35

0.9

1.9

28

2083

0.524

3.5

125

155

5×50

1

2

31

2921

0.387

3.5

160

185

5×70

1.1

2.1

36

3974

0.268

3.5

200

225

5×95

1.1

2.2

39

5297

0.193

3.5

245

270

5×120

1.2

2.4

44

6638

0.153

3.5

285

310

5×150

1.4

2.5

49

8290

0.124

3.5

325

345

5×185

1.6

2.7

55

10215

0,0991

3.5

375

390

5×240

1.7

3

64

13130

0,0754

3.5

440

450

5×300

1.8

3.2

70

16670

0,0601

3.5

505

515

Kabel Daya 3+1 inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

3×4+1×2.5

0.7

1.8

13

236

4.61

3.5

34

45

3×6+1×4

0.7

1.8

14

316

3.08

3.5

43

57

3×10+1×6

0.7

1.8

17

461

1.83

3.5

60

77

3×16+1×10

0.7

1.8

19

679

1.15

3.5

83

105

3×25+1×16

0.9

1.8

22

1065

0.727

3.5

105

125

3×35+1×16

0.9

1.8

24

1360

0.524

3.5

125

155

3×50+1×25

1

1.8

25

1901

0.387

3.5

160

185

3×70+1×35

1.1

1.9

28

2585

0.268

3.5

200

225

3×95+1×50

1.1

2

32

3518

0.193

3.5

245

270

3×120+1×70

1.2

2.1

35

4443

0.153

3.5

285

310

3×150+1×70

1.4

2.2

40

5326

0.124

3.5

325

345

3×185+1×95

1.6

2.4

43

8501

0,0991

3.5

375

390

3×240+1×120

1.7

2.5

48

11155

0,0754

3.5

440

450

3×300+1×150

1.8

2.7

54

14470

0,0601

3.5

505

515

3×400+1×240

2

3.1

66

309

0.047

3.5

570

575

Kabel Daya 3+2 inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

3×4+2×2.5

0.7

1.8

13.9

413

4.61

3.5

34

45

3×6+2×4

0.7

1.8

15.3

6682

3.08

3.5

43

57

3×10+2×6

0.7

1.8

18

603

1.83

3.5

60

77

3×16+2×10

0.7

1.8

21

888

1.15

3.5

83

105

3×25+2×16

0.9

1.8

24

1342

0.727

3.5

105

125

3×35+2×16

0.9

1.8

26

1647

0.524

3.5

125

155

3×50+2×35

1

1.9

29

2386

0.387

3.5

160

185

3×70+2×35

1.1

2

32

3201

0.268

3.5

200

225

3×95+2×50

1.1

2.1

36

4269

0.193

3.5

245

270

3×120+2×70

1.2

2.3

41

5437

0.153

3.5

285

310

3×150+2×70

1.4

2.4

44

6519

0.124

3.5

325

345

3×185+2×95

1.6

2.5

49

8101

0,0991

3.5

375

390

3×240+2×120

1.7

2.7

54

10340

0,0754

3.5

440

450

3×300+2×150

1.8

2.8

56

12810

0,0601

3.5

505

515

Kabel Daya 4+1 inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

4×4+1×2.5

0.7

1.8

14.5

331

4.61

3.5

34

45

4×6+1×4

0.7

1.8

15.9

435

3.08

3.5

43

57

4×10+1×6

0.7

1.8

18

649

1.83

3.5

60

77

4×16+1×10

0.7

1.8

21

965

1.15

3.5

83

105

4×25+1×16

0.9

1.8

25

1456

0.727

3.5

105

125

4×35+1×16

0.9

1.8

27

1863

0.524

3.5

125

155

4×50+1×25

1

1.9

29

2633

0.387

3.5

160

185

4×70+1×35

1.1

2

32

3565

0.268

3.5

200

225

4×95+1×50

1.1

2.1

36

4735

0.193

3.5

245

270

4×120+1×70

1.2

2.3

41

5977

0.153

3.5

285

310

4×150+1×70

1.4

2.4

44

7276

0.124

3.5

325

345

4×185+1×95

1.6

2.5

49

9055

0,0991

3.5

375

390

4×240+1×120

1.7

2.7

54

11567

0,0754

3.5

440

450

4×300+1×150

1.8

3.1

66

14321

0,0601

3.5

505

515

包装与运输Kita duwe klompok efisiensi sing mumpuni kanggo menehi dhukungan sing apik kanggo klien kita.Kita biasane ngetutake prinsip berorientasi pelanggan, fokus rincian kanggo Pasokan OEM / ODM 4 Inti XLPE Insulated PVC Sheathed Unarmoured Power Cable / Fleksibel Flame Retardant Power Cable, Saiki, kita ngupayakake kerjasama sing luwih gedhe karo para panuku ing luar negeri sing ditemtokake kanthi bebarengan keuntungan.Mangga aran gratis kanggo hubungi kita kanggo rincian liyane.
Suplai OEM/ODMKabel Tembaga China lan Tembaga Insulated PVC, Kanthi netepi prinsip "oriented manungsa, menang kanthi kualitas", perusahaan kita kanthi tulus nampani pedagang saka ing omah lan ing luar negeri kanggo ngunjungi kita, ngobrol bisnis karo kita lan bebarengan nggawe masa depan sing apik.


  • Sadurunge:
  • Sabanjure:

  • Tulis pesen ing kene lan kirim menyang kita