Pasokan ODM Kabel Listrik Kawat 0.6/1kv 8/15kv Unarmoured Lapis Baja Swa Sta PVC/XLPE Insulated Sheath Kabel Daya Cu Al Power Kabel Listrik

Katrangan singkat:

Kabel digunakake kanggo sumber listrik ing sistem instalasi voltase kurang, Padha cocok kanggo instalasi ing njero ruangan lan njobo, ing saluran kabel, ing lemah, ing daya lan ngoper stasiun, distribusi energi lokal, tanduran industri, ngendi ora ana risiko mechanical. karusakan.

 

 

Penerimaan: OEM/ODM, Perdagangan, Grosir, Agensi Regional

Pembayaran: T/T, L/C, PayPal


Detail Produk

Tag produk

Ora preduli pelanggan anyar utawa klien sadurunge, Kita percaya karo wektu sing suwe lan hubungan sing bisa dipercaya kanggo Pasokan ODM Kabel Listrik Kawat 0.6 / 1kv 8 / 15kv Unarmoured Armored Swa Sta PVC / XLPE Insulated Sheath Power Cable Cu Al Power Electric Cable, Kita arep kanggo kanthi sepenuh ati nampani kabeh klien nalika ing industri loro ing omah lan jaban rangkah kanggo kerjo bareng tangan, lan nggawe dawa mancorong bebarengan.
Ora ketompo customer anyar utawa klien sadurungé, Kita pracaya ing periode wektu ingkang dipun danguaken lan sesambetan dipercoyo kanggoChina Distribution Line PVC Insulated Power Cable lan Mv Power Cable, We welcome sampeyan ngunjungi perusahaan & pabrik lan showroom kita nampilake macem-macem produk lan solusi sing bakal ketemu pangarepan.Kangge, iku trep kanggo ngunjungi situs web kita.Staff sales kita bakal nyoba sing paling apik kanggo nyedhiyani sampeyan karo layanan paling apik.Yen sampeyan mbutuhake informasi luwih lengkap, aja ragu-ragu hubungi kita liwat E-mail, fax utawa telpon.

Aplikasi

Trunking kabel njero ruangan, njaba kanggo stasiun listrik, industri lan switchgear uga kanggo jaringan pasokan kutha, yen karusakan mekanis ora mungkin.

Konstruksi

avava

Karakteristik

Dirating voltase: 0.6/1kV

1. sak operasi normal kabel, suhu konduktor maksimum kudu 70 ℃ kanggo PVC jampel lan 90 ℃ kanggo XLPE jampel.
2. Suhu maksimum konduktor sajrone sirkuit cendhak (durasi maksimal ora ngluwihi 5 detik): Insulasi PVC - 160 ℃ kanggo bagean konduktor ≤300mm2, 140 ℃ kanggo bagean salib konduktor> 300mm2;Crosslinked PVC insulasi ing 250 ℃.
3. Nalika mbikak kabel, suhu sekitar ora bakal kurang saka 0 ℃, lan minimal allowable mlengkung radius minangka nderek:
Kabel inti tunggal: 20D tanpa lapis baja, 15D lapis baja
Kabel multi-inti: 15D kanggo unarmored, 12D kanggo armored
Where: D- diameteripun njaba kabel.
4. Kabel putus gaya:
Kabel inti aluminium: 40 × S (N)
Kabel inti tembaga: 70 × S (N)
Cathetan: S yaiku total area cross-sectional konduktor

Standar

IEC 60502-1, GB/T 12706.1

Paramèter

Kabel Daya Inti Tunggal

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

1×1.5

0.7

1.4

6

53

12.1

3.5

22

33

1×2.5

0.7

1.4

6

68

7.41

3.5

31

43

1×4

0.7

1.4

7

87

4.61

3.5

41

56

1×6

0.7

1.4

7

110

3.08

3.5

52

70

1×10

0.7

1.4

8

155

1.83

3.5

71

94

1×16

0.7

1.4

9

220

1.15

3.5

92

120

1×25

0.9

1.4

10

345

0.727

3.5

120

155

1×35

0.9

1.4

12

424

0.524

3.5

150

185

1×50

1

1.4

13

555

0.387

3.5

180

220

1×70

1.1

1.4

14

770

0.268

3.5

230

270

1×95

1.1

1.5

16

1040

0.193

3.5

285

320

1×120

1.2

1.5

18

1290

0.153

3.5

335

365

1×150

1.4

1.6

20

1590

0.124

3.5

385

410

1×185

1.6

1.6

22

1944

0,0991

3.5

450

465

1×240

1.7

1.7

25

2510

0,0754

3.5

535

540

1×300

1.8

1.8

27

3042

0,0601

3.5

620

610

1×400

2

1.9

31

3869

0.047

3.5

720

695

1×500

2.2

2.1

35

4910

0,0366

3.5

835

780

1×630

2.4

2.2

40

6220

0,0283

3.5

960

880

1×800

2.6

2.4

45

7870

0,0221

3.5

1110

970

1×1000

2.8

2.6

51

9804

0,0176

3.5

1230

1060

2 Kabel Daya Inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

2×2.5

0.7

1.8

11.8

151

7.41

3.5

26

35

2×4

0.7

1.8

12.7

198

4.61

3.5

34

45

2×6

0.7

1.8

13.7

250

3.08

3.5

43

57

2×10

0.7

1.8

15

374

1.83

3.5

60

77

2×16

0.7

1.8

17

518

1.15

3.5

83

105

2×25

0.9

1.8

20

772

0.727

3.5

105

125

2×35

0.9

1.8

22

1006

0.524

3.5

125

155

2×50

1

1.8

20

1365

0.387

3.5

160

185

2×70

1.1

1.8

21

1872

0.268

3.5

200

225

2×95

1.1

1.8

24

2475

0.193

3.5

245

270

2×120

1.2

1.8

27

3089

0.153

3.5

285

310

2×150

1.4

1.9

30

3834

0.124

3.5

325

345

3 Kabel Daya Inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

3×1.5

0.7

1.5

10

145

12.1

3.5

20

27

3×2.5

0.7

1.5

11

185

7.41

3.5

26

35

3×4

0.7

1.5

12

250

4.61

3.5

34

45

3×6

0.7

1.5

13

320

3.08

3.5

43

57

3×10

0.7

1.8

16

450

1.83

3.5

60

77

3×16

0.7

1.8

18

640

1.15

3.5

83

105

3×25

0.9

1.8

21

940

0.727

3.5

105

125

3×35

0.9

1.8

23

1260

0.524

3.5

125

155

3×50

1

1.8

23

1670

0.387

3.5

160

185

3×70

1.1

1.8

26

2280

0.268

3.5

200

225

3×95

1.1

1.9

30

3020

0.193

3.5

245

270

3×120

1.2

2

32

3790

0.153

3.5

285

310

3×150

1.4

2.2

37

4750

0.124

3.5

325

345

3×185

1.6

2.3

41

5654

0,0991

3.5

375

390

3×240

1.7

2.4

46

7243

0,0754

3.5

440

450

3×300

1.8

2.6

51

9465

0,0601

3.5

505

515

3×400

2

3

64

12066

0.047

3.5

570

575

4 Kabel Daya Inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

4×4

0.7

1.8

13

253

4.61

3.5

34

45

4×6

0.7

1.8

14

337

3.08

3.5

43

57

4×10

0.7

1.8

17

501

1.83

3.5

60

77

4×16

0.7

1.8

20

778

1.15

3.5

83

105

4×25

0.9

1.8

23

1160

0.727

3.5

105

125

4×35

0.9

1.8

25

1554

0.524

3.5

125

155

4×50

1

1.8

23

2148

0.387

3.5

160

185

4×70

1.1

1.8

27

2928

0.268

3.5

200

225

4×95

1.1

1.9

31

3854

0.193

3.5

245

270

4×120

1.2

2

33

4925

0.153

3.5

285

310

4×150

1.4

2.2

38

6238

0.124

3.5

325

345

4×185

1.6

2.3

42

7562

0,0991

3.5

375

390

4×240

1.7

2.5

47

9836

0,0754

3.5

440

450

4×300

1.8

2.6

52

12550

0,0601

3.5

505

515

4×400

2

3.1

66

15929

0.047

3.5

570

575

5 Kabel Daya Inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

5×4

0.7

1.8

14.5

349

4.61

3.5

34

45

5×6

0.7

1.8

15.8

460

3.08

3.5

43

57

5×10

0.7

1.8

19

699

1.83

3.5

60

77

5×16

0.7

1.8

22

1013

1.15

3.5

83

105

5×25

0.9

1.8

25

1566

0.727

3.5

105

125

5×35

0.9

1.9

28

2083

0.524

3.5

125

155

5×50

1

2

31

2921

0.387

3.5

160

185

5×70

1.1

2.1

36

3974

0.268

3.5

200

225

5×95

1.1

2.2

39

5297

0.193

3.5

245

270

5×120

1.2

2.4

44

6638

0.153

3.5

285

310

5×150

1.4

2.5

49

8290

0.124

3.5

325

345

5×185

1.6

2.7

55

10215

0,0991

3.5

375

390

5×240

1.7

3

64

13130

0,0754

3.5

440

450

5×300

1.8

3.2

70

16670

0,0601

3.5

505

515

Kabel Daya 3+1 inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

3×4+1×2.5

0.7

1.8

13

236

4.61

3.5

34

45

3×6+1×4

0.7

1.8

14

316

3.08

3.5

43

57

3×10+1×6

0.7

1.8

17

461

1.83

3.5

60

77

3×16+1×10

0.7

1.8

19

679

1.15

3.5

83

105

3×25+1×16

0.9

1.8

22

1065

0.727

3.5

105

125

3×35+1×16

0.9

1.8

24

1360

0.524

3.5

125

155

3×50+1×25

1

1.8

25

1901

0.387

3.5

160

185

3×70+1×35

1.1

1.9

28

2585

0.268

3.5

200

225

3×95+1×50

1.1

2

32

3518

0.193

3.5

245

270

3×120+1×70

1.2

2.1

35

4443

0.153

3.5

285

310

3×150+1×70

1.4

2.2

40

5326

0.124

3.5

325

345

3×185+1×95

1.6

2.4

43

8501

0,0991

3.5

375

390

3×240+1×120

1.7

2.5

48

11155

0,0754

3.5

440

450

3×300+1×150

1.8

2.7

54

14470

0,0601

3.5

505

515

3×400+1×240

2

3.1

66

309

0.047

3.5

570

575

Kabel Daya 3+2 inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

3×4+2×2.5

0.7

1.8

13.9

413

4.61

3.5

34

45

3×6+2×4

0.7

1.8

15.3

6682

3.08

3.5

43

57

3×10+2×6

0.7

1.8

18

603

1.83

3.5

60

77

3×16+2×10

0.7

1.8

21

888

1.15

3.5

83

105

3×25+2×16

0.9

1.8

24

1342

0.727

3.5

105

125

3×35+2×16

0.9

1.8

26

1647

0.524

3.5

125

155

3×50+2×35

1

1.9

29

2386

0.387

3.5

160

185

3×70+2×35

1.1

2

32

3201

0.268

3.5

200

225

3×95+2×50

1.1

2.1

36

4269

0.193

3.5

245

270

3×120+2×70

1.2

2.3

41

5437

0.153

3.5

285

310

3×150+2×70

1.4

2.4

44

6519

0.124

3.5

325

345

3×185+2×95

1.6

2.5

49

8101

0,0991

3.5

375

390

3×240+2×120

1.7

2.7

54

10340

0,0754

3.5

440

450

3×300+2×150

1.8

2.8

56

12810

0,0601

3.5

505

515

Kabel Daya 4+1 inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

4×4+1×2.5

0.7

1.8

14.5

331

4.61

3.5

34

45

4×6+1×4

0.7

1.8

15.9

435

3.08

3.5

43

57

4×10+1×6

0.7

1.8

18

649

1.83

3.5

60

77

4×16+1×10

0.7

1.8

21

965

1.15

3.5

83

105

4×25+1×16

0.9

1.8

25

1456

0.727

3.5

105

125

4×35+1×16

0.9

1.8

27

1863

0.524

3.5

125

155

4×50+1×25

1

1.9

29

2633

0.387

3.5

160

185

4×70+1×35

1.1

2

32

3565

0.268

3.5

200

225

4×95+1×50

1.1

2.1

36

4735

0.193

3.5

245

270

4×120+1×70

1.2

2.3

41

5977

0.153

3.5

285

310

4×150+1×70

1.4

2.4

44

7276

0.124

3.5

325

345

4×185+1×95

1.6

2.5

49

9055

0,0991

3.5

375

390

4×240+1×120

1.7

2.7

54

11567

0,0754

3.5

440

450

4×300+1×150

1.8

3.1

66

14321

0,0601

3.5

505

515

Ora preduli pelanggan anyar utawa klien sadurunge, Kita percaya karo wektu sing suwe lan hubungan sing bisa dipercaya kanggo Pasokan ODM Kabel Listrik Kawat 0.6 / 1kv 8 / 15kv Unarmoured Armored Swa Sta PVC / XLPE Insulated Sheath Power Cable Cu Al Power Electric Cable, Kita arep kanggo kanthi sepenuh ati nampani kabeh klien nalika ing industri loro ing omah lan jaban rangkah kanggo kerjo bareng tangan, lan nggawe dawa mancorong bebarengan.
Pasokan ODMChina Distribution Line PVC Insulated Power Cable lan Mv Power Cable, We welcome sampeyan ngunjungi perusahaan & pabrik lan showroom kita nampilake macem-macem produk lan solusi sing bakal ketemu pangarepan.Kangge, iku trep kanggo ngunjungi situs web kita.Staff sales kita bakal nyoba sing paling apik kanggo nyedhiyani sampeyan karo layanan paling apik.Yen sampeyan mbutuhake informasi luwih lengkap, aja ragu-ragu hubungi kita liwat E-mail, fax utawa telpon.


  • Sadurunge:
  • Sabanjure:

  • Tulis pesen ing kene lan kirim menyang kita