Pengiriman Baru untuk 0.6/1kv Listrik Aluminium Konduktor PVC/XLPE/PE Insulated PVC Sheathed Low/Medium Voltag Kabel Daya Listrik
Umume kita percaya yen karakter mutusake produk sing apik banget, rincian mutusake kualitas produk sing apik, kanthi kabeh semangat klompok REALISTIS, EFISIEN lan INOVATIF kanggo Pangiriman Anyar kanggo 0.6 / 1kv Konduktor Aluminium Listrik PVC / XLPE / PE Insulated PVC Sheathed Low / Medium Kabel Daya Listrik Voltag, We warmly welcome bakul saka ngarep lan luar negeri kanggo nelpon kita lan nggawe hubungan bisnis karo kita, lan kita bakal nindakake sing paling apik kanggo ngawula sampeyan.
Umume kita percaya yen karakter mutusake produk sing apik banget, rincian mutusake kualitas produk sing apik, kanthi semangat klompok sing REALISTIK, EFISIEN lan INOVATIF.Kabel Listrik China lan Kabel Listrik, Tim teknik sing mumpuni biasane bakal siyap ngladeni sampeyan kanggo konsultasi lan umpan balik.Kita uga bisa ngirim sampeyan kanthi conto gratis kanggo nyukupi kabutuhan sampeyan.Upaya paling apik bisa uga ditindakake kanggo nawakake layanan lan produk lan solusi sing cocog.Kanggo sapa waé sing kasengsem ing perusahaan lan barang, sampeyan kudu nggawe kontak karo kita kanthi ngirim email utawa hubungi kita langsung.Supaya ngerti solusi lan organisasi kita.ar liyane, sampeyan bisa teka menyang pabrik kita kanggo nemtokake iku.Biasane kita bakal nampa tamu saka sak ndonya menyang perusahaan kita.o nggawe hubungan bisnis cilik karo kita.Sampeyan mesthi ora duwe biaya kanggo ngomong karo kita kanggo perusahaan.Lan kita yakin kita bakal nuduhake pengalaman praktis dagang sing paling efektif karo kabeh pedagang.
Aplikasi
Trunking kabel njero ruangan, njaba kanggo stasiun listrik, industri lan switchgear uga kanggo jaringan pasokan kutha, yen karusakan mekanis ora mungkin.
Konstruksi
Karakteristik
Dirating voltase: 0.6/1kV
1. sak operasi normal kabel, suhu konduktor maksimum kudu 70 ℃ kanggo PVC jampel lan 90 ℃ kanggo XLPE jampel.
2. Suhu maksimum konduktor sajrone sirkuit cendhak (durasi maksimal ora ngluwihi 5 detik): Insulasi PVC - 160 ℃ kanggo bagean konduktor ≤300mm2, 140 ℃ kanggo bagean salib konduktor> 300mm2;Crosslinked PVC insulasi ing 250 ℃.
3. Nalika mbikak kabel, suhu sekitar ora bakal kurang saka 0 ℃, lan minimal allowable mlengkung radius minangka nderek:
Kabel inti tunggal: 20D tanpa lapis baja, 15D lapis baja
Kabel multi-inti: 15D kanggo unarmored, 12D kanggo armored
Where: D- diameteripun njaba kabel.
4. Kabel putus gaya:
Kabel inti aluminium: 40 × S (N)
Kabel inti tembaga: 70 × S (N)
Cathetan: S yaiku total area cross-sectional konduktor
Standar
IEC 60502-1, GB/T 12706.1
Paramèter
Kabel Daya Inti Tunggal | ||||||||
Nom.Cross-bagean saka konduktor | Ketebalan Isolasi | Ketebalan Sarung | Kira-kira.OD | Kira-kira Bobot | Maks.Resistansi DC Konduktor (20°C) | Tes Tegangan AC | Rating saiki | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV / 5 min | Ing udara (A) | Ing lemah (A) |
1×1.5 | 0.7 | 1.4 | 6 | 53 | 12.1 | 3.5 | 22 | 33 |
1×2.5 | 0.7 | 1.4 | 6 | 68 | 7.41 | 3.5 | 31 | 43 |
1×4 | 0.7 | 1.4 | 7 | 87 | 4.61 | 3.5 | 41 | 56 |
1×6 | 0.7 | 1.4 | 7 | 110 | 3.08 | 3.5 | 52 | 70 |
1×10 | 0.7 | 1.4 | 8 | 155 | 1.83 | 3.5 | 71 | 94 |
1×16 | 0.7 | 1.4 | 9 | 220 | 1.15 | 3.5 | 92 | 120 |
1×25 | 0.9 | 1.4 | 10 | 345 | 0.727 | 3.5 | 120 | 155 |
1×35 | 0.9 | 1.4 | 12 | 424 | 0.524 | 3.5 | 150 | 185 |
1×50 | 1 | 1.4 | 13 | 555 | 0.387 | 3.5 | 180 | 220 |
1×70 | 1.1 | 1.4 | 14 | 770 | 0.268 | 3.5 | 230 | 270 |
1×95 | 1.1 | 1.5 | 16 | 1040 | 0.193 | 3.5 | 285 | 320 |
1×120 | 1.2 | 1.5 | 18 | 1290 | 0.153 | 3.5 | 335 | 365 |
1×150 | 1.4 | 1.6 | 20 | 1590 | 0.124 | 3.5 | 385 | 410 |
1×185 | 1.6 | 1.6 | 22 | 1944 | 0,0991 | 3.5 | 450 | 465 |
1×240 | 1.7 | 1.7 | 25 | 2510 | 0,0754 | 3.5 | 535 | 540 |
1×300 | 1.8 | 1.8 | 27 | 3042 | 0,0601 | 3.5 | 620 | 610 |
1×400 | 2 | 1.9 | 31 | 3869 | 0.047 | 3.5 | 720 | 695 |
1×500 | 2.2 | 2.1 | 35 | 4910 | 0,0366 | 3.5 | 835 | 780 |
1×630 | 2.4 | 2.2 | 40 | 6220 | 0,0283 | 3.5 | 960 | 880 |
1×800 | 2.6 | 2.4 | 45 | 7870 | 0,0221 | 3.5 | 1110 | 970 |
1×1000 | 2.8 | 2.6 | 51 | 9804 | 0,0176 | 3.5 | 1230 | 1060 |
2 Kabel Daya Inti | ||||||||
Nom.Cross-bagean saka konduktor | Ketebalan Isolasi | Ketebalan Sarung | Kira-kira.OD | Kira-kira Bobot | Maks.Resistansi DC Konduktor (20°C) | Tes Tegangan AC | Rating saiki | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV / 5 min | Ing udara (A) | Ing lemah (A) |
2×2.5 | 0.7 | 1.8 | 11.8 | 151 | 7.41 | 3.5 | 26 | 35 |
2×4 | 0.7 | 1.8 | 12.7 | 198 | 4.61 | 3.5 | 34 | 45 |
2×6 | 0.7 | 1.8 | 13.7 | 250 | 3.08 | 3.5 | 43 | 57 |
2×10 | 0.7 | 1.8 | 15 | 374 | 1.83 | 3.5 | 60 | 77 |
2×16 | 0.7 | 1.8 | 17 | 518 | 1.15 | 3.5 | 83 | 105 |
2×25 | 0.9 | 1.8 | 20 | 772 | 0.727 | 3.5 | 105 | 125 |
2×35 | 0.9 | 1.8 | 22 | 1006 | 0.524 | 3.5 | 125 | 155 |
2×50 | 1 | 1.8 | 20 | 1365 | 0.387 | 3.5 | 160 | 185 |
2×70 | 1.1 | 1.8 | 21 | 1872 | 0.268 | 3.5 | 200 | 225 |
2×95 | 1.1 | 1.8 | 24 | 2475 | 0.193 | 3.5 | 245 | 270 |
2×120 | 1.2 | 1.8 | 27 | 3089 | 0.153 | 3.5 | 285 | 310 |
2×150 | 1.4 | 1.9 | 30 | 3834 | 0.124 | 3.5 | 325 | 345 |
3 Kabel Daya Inti | ||||||||
Nom.Cross-bagean saka konduktor | Ketebalan Isolasi | Ketebalan Sarung | Kira-kira.OD | Kira-kira Bobot | Maks.Resistansi DC Konduktor (20°C) | Tes Tegangan AC | Rating saiki | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV / 5 min | Ing udara (A) | Ing lemah (A) |
3×1.5 | 0.7 | 1.5 | 10 | 145 | 12.1 | 3.5 | 20 | 27 |
3×2.5 | 0.7 | 1.5 | 11 | 185 | 7.41 | 3.5 | 26 | 35 |
3×4 | 0.7 | 1.5 | 12 | 250 | 4.61 | 3.5 | 34 | 45 |
3×6 | 0.7 | 1.5 | 13 | 320 | 3.08 | 3.5 | 43 | 57 |
3×10 | 0.7 | 1.8 | 16 | 450 | 1.83 | 3.5 | 60 | 77 |
3×16 | 0.7 | 1.8 | 18 | 640 | 1.15 | 3.5 | 83 | 105 |
3×25 | 0.9 | 1.8 | 21 | 940 | 0.727 | 3.5 | 105 | 125 |
3×35 | 0.9 | 1.8 | 23 | 1260 | 0.524 | 3.5 | 125 | 155 |
3×50 | 1 | 1.8 | 23 | 1670 | 0.387 | 3.5 | 160 | 185 |
3×70 | 1.1 | 1.8 | 26 | 2280 | 0.268 | 3.5 | 200 | 225 |
3×95 | 1.1 | 1.9 | 30 | 3020 | 0.193 | 3.5 | 245 | 270 |
3×120 | 1.2 | 2 | 32 | 3790 | 0.153 | 3.5 | 285 | 310 |
3×150 | 1.4 | 2.2 | 37 | 4750 | 0.124 | 3.5 | 325 | 345 |
3×185 | 1.6 | 2.3 | 41 | 5654 | 0,0991 | 3.5 | 375 | 390 |
3×240 | 1.7 | 2.4 | 46 | 7243 | 0,0754 | 3.5 | 440 | 450 |
3×300 | 1.8 | 2.6 | 51 | 9465 | 0,0601 | 3.5 | 505 | 515 |
3×400 | 2 | 3 | 64 | 12066 | 0.047 | 3.5 | 570 | 575 |
4 Kabel Daya Inti | ||||||||
Nom.Cross-bagean saka konduktor | Ketebalan Isolasi | Ketebalan Sarung | Kira-kira.OD | Kira-kira Bobot | Maks.Resistansi DC Konduktor (20°C) | Tes Tegangan AC | Rating saiki | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV / 5 min | Ing udara (A) | Ing lemah (A) |
4×4 | 0.7 | 1.8 | 13 | 253 | 4.61 | 3.5 | 34 | 45 |
4×6 | 0.7 | 1.8 | 14 | 337 | 3.08 | 3.5 | 43 | 57 |
4×10 | 0.7 | 1.8 | 17 | 501 | 1.83 | 3.5 | 60 | 77 |
4×16 | 0.7 | 1.8 | 20 | 778 | 1.15 | 3.5 | 83 | 105 |
4×25 | 0.9 | 1.8 | 23 | 1160 | 0.727 | 3.5 | 105 | 125 |
4×35 | 0.9 | 1.8 | 25 | 1554 | 0.524 | 3.5 | 125 | 155 |
4×50 | 1 | 1.8 | 23 | 2148 | 0.387 | 3.5 | 160 | 185 |
4×70 | 1.1 | 1.8 | 27 | 2928 | 0.268 | 3.5 | 200 | 225 |
4×95 | 1.1 | 1.9 | 31 | 3854 | 0.193 | 3.5 | 245 | 270 |
4×120 | 1.2 | 2 | 33 | 4925 | 0.153 | 3.5 | 285 | 310 |
4×150 | 1.4 | 2.2 | 38 | 6238 | 0.124 | 3.5 | 325 | 345 |
4×185 | 1.6 | 2.3 | 42 | 7562 | 0,0991 | 3.5 | 375 | 390 |
4×240 | 1.7 | 2.5 | 47 | 9836 | 0,0754 | 3.5 | 440 | 450 |
4×300 | 1.8 | 2.6 | 52 | 12550 | 0,0601 | 3.5 | 505 | 515 |
4×400 | 2 | 3.1 | 66 | 15929 | 0.047 | 3.5 | 570 | 575 |
5 Kabel Daya Inti | ||||||||
Nom.Cross-bagean saka konduktor | Ketebalan Isolasi | Ketebalan Sarung | Kira-kira.OD | Kira-kira Bobot | Maks.Resistansi DC Konduktor (20°C) | Tes Tegangan AC | Rating saiki | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV / 5 min | Ing udara (A) | Ing lemah (A) |
5×4 | 0.7 | 1.8 | 14.5 | 349 | 4.61 | 3.5 | 34 | 45 |
5×6 | 0.7 | 1.8 | 15.8 | 460 | 3.08 | 3.5 | 43 | 57 |
5×10 | 0.7 | 1.8 | 19 | 699 | 1.83 | 3.5 | 60 | 77 |
5×16 | 0.7 | 1.8 | 22 | 1013 | 1.15 | 3.5 | 83 | 105 |
5×25 | 0.9 | 1.8 | 25 | 1566 | 0.727 | 3.5 | 105 | 125 |
5×35 | 0.9 | 1.9 | 28 | 2083 | 0.524 | 3.5 | 125 | 155 |
5×50 | 1 | 2 | 31 | 2921 | 0.387 | 3.5 | 160 | 185 |
5×70 | 1.1 | 2.1 | 36 | 3974 | 0.268 | 3.5 | 200 | 225 |
5×95 | 1.1 | 2.2 | 39 | 5297 | 0.193 | 3.5 | 245 | 270 |
5×120 | 1.2 | 2.4 | 44 | 6638 | 0.153 | 3.5 | 285 | 310 |
5×150 | 1.4 | 2.5 | 49 | 8290 | 0.124 | 3.5 | 325 | 345 |
5×185 | 1.6 | 2.7 | 55 | 10215 | 0,0991 | 3.5 | 375 | 390 |
5×240 | 1.7 | 3 | 64 | 13130 | 0,0754 | 3.5 | 440 | 450 |
5×300 | 1.8 | 3.2 | 70 | 16670 | 0,0601 | 3.5 | 505 | 515 |
Kabel Daya 3+1 inti | ||||||||
Nom.Cross-bagean saka konduktor | Ketebalan Isolasi | Ketebalan Sarung | Kira-kira.OD | Kira-kira Bobot | Maks.Resistansi DC Konduktor (20°C) | Tes Tegangan AC | Rating saiki | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV / 5 min | Ing udara (A) | Ing lemah (A) |
3×4+1×2.5 | 0.7 | 1.8 | 13 | 236 | 4.61 | 3.5 | 34 | 45 |
3×6+1×4 | 0.7 | 1.8 | 14 | 316 | 3.08 | 3.5 | 43 | 57 |
3×10+1×6 | 0.7 | 1.8 | 17 | 461 | 1.83 | 3.5 | 60 | 77 |
3×16+1×10 | 0.7 | 1.8 | 19 | 679 | 1.15 | 3.5 | 83 | 105 |
3×25+1×16 | 0.9 | 1.8 | 22 | 1065 | 0.727 | 3.5 | 105 | 125 |
3×35+1×16 | 0.9 | 1.8 | 24 | 1360 | 0.524 | 3.5 | 125 | 155 |
3×50+1×25 | 1 | 1.8 | 25 | 1901 | 0.387 | 3.5 | 160 | 185 |
3×70+1×35 | 1.1 | 1.9 | 28 | 2585 | 0.268 | 3.5 | 200 | 225 |
3×95+1×50 | 1.1 | 2 | 32 | 3518 | 0.193 | 3.5 | 245 | 270 |
3×120+1×70 | 1.2 | 2.1 | 35 | 4443 | 0.153 | 3.5 | 285 | 310 |
3×150+1×70 | 1.4 | 2.2 | 40 | 5326 | 0.124 | 3.5 | 325 | 345 |
3×185+1×95 | 1.6 | 2.4 | 43 | 8501 | 0,0991 | 3.5 | 375 | 390 |
3×240+1×120 | 1.7 | 2.5 | 48 | 11155 | 0,0754 | 3.5 | 440 | 450 |
3×300+1×150 | 1.8 | 2.7 | 54 | 14470 | 0,0601 | 3.5 | 505 | 515 |
3×400+1×240 | 2 | 3.1 | 66 | 309 | 0.047 | 3.5 | 570 | 575 |
Kabel Daya 3+2 inti | ||||||||
Nom.Cross-bagean saka konduktor | Ketebalan Isolasi | Ketebalan Sarung | Kira-kira.OD | Kira-kira Bobot | Maks.Resistansi DC Konduktor (20°C) | Tes Tegangan AC | Rating saiki | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV / 5 min | Ing udara (A) | Ing lemah (A) |
3×4+2×2.5 | 0.7 | 1.8 | 13.9 | 413 | 4.61 | 3.5 | 34 | 45 |
3×6+2×4 | 0.7 | 1.8 | 15.3 | 6682 | 3.08 | 3.5 | 43 | 57 |
3×10+2×6 | 0.7 | 1.8 | 18 | 603 | 1.83 | 3.5 | 60 | 77 |
3×16+2×10 | 0.7 | 1.8 | 21 | 888 | 1.15 | 3.5 | 83 | 105 |
3×25+2×16 | 0.9 | 1.8 | 24 | 1342 | 0.727 | 3.5 | 105 | 125 |
3×35+2×16 | 0.9 | 1.8 | 26 | 1647 | 0.524 | 3.5 | 125 | 155 |
3×50+2×35 | 1 | 1.9 | 29 | 2386 | 0.387 | 3.5 | 160 | 185 |
3×70+2×35 | 1.1 | 2 | 32 | 3201 | 0.268 | 3.5 | 200 | 225 |
3×95+2×50 | 1.1 | 2.1 | 36 | 4269 | 0.193 | 3.5 | 245 | 270 |
3×120+2×70 | 1.2 | 2.3 | 41 | 5437 | 0.153 | 3.5 | 285 | 310 |
3×150+2×70 | 1.4 | 2.4 | 44 | 6519 | 0.124 | 3.5 | 325 | 345 |
3×185+2×95 | 1.6 | 2.5 | 49 | 8101 | 0,0991 | 3.5 | 375 | 390 |
3×240+2×120 | 1.7 | 2.7 | 54 | 10340 | 0,0754 | 3.5 | 440 | 450 |
3×300+2×150 | 1.8 | 2.8 | 56 | 12810 | 0,0601 | 3.5 | 505 | 515 |
Kabel Daya 4+1 inti | ||||||||
Nom.Cross-bagean saka konduktor | Ketebalan Isolasi | Ketebalan Sarung | Kira-kira.OD | Kira-kira Bobot | Maks.Resistansi DC Konduktor (20°C) | Tes Tegangan AC | Rating saiki | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV / 5 min | Ing udara (A) | Ing lemah (A) |
4×4+1×2.5 | 0.7 | 1.8 | 14.5 | 331 | 4.61 | 3.5 | 34 | 45 |
4×6+1×4 | 0.7 | 1.8 | 15.9 | 435 | 3.08 | 3.5 | 43 | 57 |
4×10+1×6 | 0.7 | 1.8 | 18 | 649 | 1.83 | 3.5 | 60 | 77 |
4×16+1×10 | 0.7 | 1.8 | 21 | 965 | 1.15 | 3.5 | 83 | 105 |
4×25+1×16 | 0.9 | 1.8 | 25 | 1456 | 0.727 | 3.5 | 105 | 125 |
4×35+1×16 | 0.9 | 1.8 | 27 | 1863 | 0.524 | 3.5 | 125 | 155 |
4×50+1×25 | 1 | 1.9 | 29 | 2633 | 0.387 | 3.5 | 160 | 185 |
4×70+1×35 | 1.1 | 2 | 32 | 3565 | 0.268 | 3.5 | 200 | 225 |
4×95+1×50 | 1.1 | 2.1 | 36 | 4735 | 0.193 | 3.5 | 245 | 270 |
4×120+1×70 | 1.2 | 2.3 | 41 | 5977 | 0.153 | 3.5 | 285 | 310 |
4×150+1×70 | 1.4 | 2.4 | 44 | 7276 | 0.124 | 3.5 | 325 | 345 |
4×185+1×95 | 1.6 | 2.5 | 49 | 9055 | 0,0991 | 3.5 | 375 | 390 |
4×240+1×120 | 1.7 | 2.7 | 54 | 11567 | 0,0754 | 3.5 | 440 | 450 |
4×300+1×150 | 1.8 | 3.1 | 66 | 14321 | 0,0601 | 3.5 | 505 | 515 |
Umume kita percaya yen karakter mutusake produk sing apik banget, rincian mutusake kualitas produk sing apik, kanthi kabeh semangat klompok REALISTIS, EFISIEN lan INOVATIF kanggo Pangiriman Anyar kanggo 0.6 / 1kv Konduktor Aluminium Listrik PVC / XLPE / PE Insulated PVC Sheathed Low / Medium Kabel Daya Listrik Voltag, We warmly welcome bakul saka ngarep lan luar negeri kanggo nelpon kita lan nggawe hubungan bisnis karo kita, lan kita bakal nindakake sing paling apik kanggo ngawula sampeyan.
Pangiriman anyar kanggoKabel Listrik China lan Kabel Listrik, Tim teknik sing mumpuni biasane bakal siyap ngladeni sampeyan kanggo konsultasi lan umpan balik.Kita uga bisa ngirim sampeyan kanthi conto gratis kanggo nyukupi kabutuhan sampeyan.Upaya paling apik bisa uga ditindakake kanggo nawakake layanan lan produk lan solusi sing cocog.Kanggo sapa waé sing kasengsem ing perusahaan lan barang, sampeyan kudu nggawe kontak karo kita kanthi ngirim email utawa hubungi kita langsung.Supaya ngerti solusi lan organisasi kita.ar liyane, sampeyan bisa teka menyang pabrik kita kanggo nemtokake iku.Biasane kita bakal nampa tamu saka sak ndonya menyang perusahaan kita.o nggawe hubungan bisnis cilik karo kita.Sampeyan mesthi ora duwe biaya kanggo ngomong karo kita kanggo perusahaan.Lan kita yakin kita bakal nuduhake pengalaman praktis dagang sing paling efektif karo kabeh pedagang.