Kualitas apik 0.6/1kv Tegangan Rendah Tembaga/Aluminium Konduktor XLPE Insulated PVC Sheathed Steel Wire Armored Power Cable

Katrangan singkat:

0.6/1kv Xlpe terisolasi Pvc kabel daya aluminium sheathed digunakake kanggo distribusi daya ing pembangkit listrik, instalasi industri lan switchgears, uga ing utama lokal.Bisa nanggung traksi tartamtu sajrone instalasi.Kanggo instalasi tetep ing lemah.

 

 

Penerimaan: OEM/ODM, Perdagangan, Grosir, Agensi Regional

Pembayaran: T/T, L/C, PayPal

Sampel Saham Gratis & Kasedhiya


Detail Produk

Tag produk

Nalika nggunakake filosofi perusahaan "Berorientasi Klien", metode manajemen kualitas dhuwur sing nuntut, produk prodhuksi inovatif lan uga tenaga kerja R&D sing kuat, kita mesthi ngirim barang dagangan kualitas premium, solusi sing paling apik lan rega adol agresif kanggo Tegangan Rendah 0.6 / 1kv kualitas apik. Underground Copper / Aluminium Conductor XLPE Insulated PVC Sheathed Steel Wire Armored Power Cable, Perusahaan kita seneng banget karo kanca-kanca saka sak ndonya kanggo ngunjungi, neliti lan negosiasi bisnis.
Nalika nggunakake filosofi perusahaan "Berorientasi Klien", metode manajemen kualitas sing nuntut, produk prodhuksi inovatif lan uga tenaga kerja R&D sing kuat, kita mesthi ngirim barang dagangan kualitas premium, solusi sing paling apik lan rega jual sing agresif kanggoKabel China lan Kabel Listrik, Nyedhiyakake produk lan solusi sing paling apik, layanan sing paling sampurna kanthi rega sing paling terjangkau yaiku prinsip kita.Kita uga nampa pesenan OEM lan ODM. Dedicated kanggo kontrol kualitas sing ketat lan layanan pelanggan sing wicaksana, kita tansah kasedhiya kanggo ngrembug syarat sampeyan lan njamin kepuasan pelanggan lengkap.We Sincerely welcome kanca teka rembugan bisnis lan miwiti kerjasama.

Aplikasi

Digunakake ing njero ruangan, ing trowongan utawa parit kabel, kabel sing ora nganggo waja ora bisa nahan gaya mekanik eksternal.

Konstruksi

AVAV

Karakteristik

voltase dirating 0,6/1 kV
Konduktor alumunium
Isolasi XLPE
Sarung PVC
inti 1, 2, 3, 4, 5, 3+1, 3+2, 4+1
warna Black utawa Customized

Standar

GB/T 12706, IEC, BS, DIN lan ICEA miturut panyuwunan

Paramèter

Kabel Daya Aluminium 2 inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

2×4

0.7

1.8

11.4

150

7.41

3.5

34

45

2×6

0.7

1.8

12.4

171

4.61

3.5

43

57

2×10

0.7

1.8

14.9

238

3.08

3.5

60

77

2×16

0.7

1.8

17.1

294

1.91

3.5

83

105

2×25

0.9

1.8

20

394

1.2

3.5

105

125

2×35

0.9

1.8

22

484

0.868

3.5

125

155

2×50

1

1.8

23.4

497

0.641

3.5

160

185

2×70

1.1

1.8

24.5

640

0.443

3.5

200

225

2×95

1.1

1.9

28.6

827

0.32

3.5

245

270

2×120

1.2

2

29.7

1015

0.253

3.5

285

310

2×150

1.4

2.2

31.2

1268

0.206

3.5

325

345

Kabel Daya Aluminium 3 Inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

3×4

0.7

1.8

12

163

7.41

3.5

34

45

3×6

0.7

1.8

13

191

4.61

3.5

43

57

3×10

0.7

1.8

15.8

282

3.08

3.5

60

77

3×16

0.7

1.8

18.2

358

1.91

3.5

83

105

3×25

0.9

1.8

21.3

491

1.2

3.5

105

125

3×35

0.9

1.8

23.6

600

0.868

3.5

125

155

3×50

1

1.8

23.8

729

0.641

3.5

160

185

3×70

1.1

1.9

27.4

958

0.443

3.5

200

225

3×95

1.1

2

33.1

1242

0.32

3.5

245

270

3×120

1.2

2.1

34.7

1502

0.253

3.5

285

310

3×150

1.4

2.3

39.1

1875

0.206

3.5

325

345

3×185

1.6

2.4

42.3

2264

0.164

3.5

375

390

3×240

1.7

2.6

47.8

2861

0.125

3.5

440

450

3×300

1.8

2.8

52.4

3501

0.1

3.5

505

515

3×400

2

3.1

62.9

4627

0,0778

3.5

570

575

Kabel Daya Aluminium 4 Inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

4×4

0.7

1.8

13

197

7.41

3.5

34

45

4×6

0.7

1.8

14.2

233

4.61

3.5

43

57

4×10

0.7

1.8

17.2

345

3.08

3.5

60

77

4×16

0.7

1.8

19.9

442

1.91

3.5

83

105

4×25

0.9

1.8

23.4

595

1.2

3.5

105

125

4×35

0.9

1.8

25.8

734

0.868

3.5

125

155

4×50

1

1.9

27.2

912

0.641

3.5

160

185

4×70

1.1

2

27.9

1207

0.443

3.5

200

225

4×95

1.1

2.1

33.8

1569

0.32

3.5

245

270

4×120

1.2

2.3

35.8

1923

0.253

3.5

285

310

4×150

1.4

2.4

40.2

2374

0.206

3.5

325

345

4×185

1.6

2.6

43.6

2899

0.164

3.5

375

390

4×240

1.7

2.8

49.3

3670

0.125

3.5

440

450

4×300

1.8

3

54.1

4499

0.1

3.5

505

515

4×400

2

3.3

65.1

5947

0,0778

3.5

570

575

Kabel Daya Aluminium 5 Inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

5×4

0.7

1.8

14

223

7.41

3.5

34

45

5×6

0.7

1.8

15.3

266

4.61

3.5

43

57

5×10

0.7

1.8

18.7

395

3.08

3.5

60

77

5×16

0.7

1.8

21.7

512

1.91

3.5

83

105

5×25

0.9

1.8

25.6

700

1.2

3.5

105

125

5×35

0.9

1.8

28.3

872

0.868

3.5

125

155

5×50

1

2

31.6

1155

0.641

3.5

160

185

5×70

1.1

2.1

37.2

1536

0.443

3.5

200

225

5×95

1.1

2.3

41

1971

0.32

3.5

245

270

5×120

1.2

2.4

46.2

2430

0.253

3.5

285

310

5×150

1.4

2.6

50.8

3036

0.206

3.5

325

345

5×185

1.6

2.8

56.6

3716

0.164

3.5

375

390

5×240

1.7

3

62.8

4677

0.125

3.5

440

450

5×300

1.8

3.2

71.4

5758

0.1

3.5

505

515

Kabel Daya Aluminium 3+1 inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

3×4 + 1×2,5

0.7

1.8

12.7

189

7.41

3.5

34

45

3×6 + 1×4

0.7

1.8

13.9

224

4.61

3.5

43

57

3×10 + 1×6

0.7

1.8

16.4

311

3.08

3.5

60

77

3×16 + 1×10

0.7

1.8

19.2

418

1.91

3.5

83

105

3×25 + 1×16

0.9

1.8

22.5

557

1.2

3.5

105

125

3×35 + 1×16

0.9

1.8

25

667

0.868

3.5

125

155

3×50 + 1×25

1

1.8

25.5

833

0.641

3.5

160

185

3×70 + 1×35

1.1

1.9

28.9

1096

0.443

3.5

200

225

3×95 + 1×50

1.1

2.1

35.3

1448

0.32

3.5

245

270

3×120 + 1×70

1.2

2.2

37.1

1787

0.253

3.5

285

310

3×150 + 1×70

1.4

2.3

41.7

2143

0.206

3.5

325

345

3×185 + 1×95

1.6

2.5

45.3

2629

0.164

3.5

375

390

3×240 + 1×120

1.7

2.7

51.3

3314

0.125

3.5

440

450

3×300 + 1×150

1.8

2.9

56.3

4062

0.1

3.5

505

515

3×400 + 1×240

2

3.1

67.6

5295

0,0778

3.5

570

575

Kabel Daya Aluminium 3+2 inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

3×4 + 2×2,5

0.7

1.8

13.5

208

7.41

3.5

34

45

3×6 + 2×4

0.7

1.8

14.8

249

4.61

3.5

43

57

3×10 + 2×6

0.7

1.8

17.4

343

3.08

3.5

60

77

3×16 + 2×10

0.7

1.8

20.5

465

1.91

3.5

83

105

3×25 + 2×16

0.9

1.8

24

625

1.2

3.5

105

125

3×35 + 2×16

0.9

1.8

25.7

728

0.868

3.5

125

155

3×50 + 2×35

1

1.9

29

980

0.641

3.5

160

185

3×70 + 2×35

1.1

2

33.8

1284

0.443

3.5

200

225

3×95 + 2×50

1.1

2.2

37.4

1660

0.32

3.5

245

270

3×120 + 2×70

1.2

2.3

42.8

2089

0.253

3.5

285

310

3×150 + 2×70

1.4

2.4

45.2

2424

0.206

3.5

325

345

3×185 + 2×95

1.6

2.6

50.6

3010

0.164

3.5

375

390

3×240 + 2×120

1.7

2.8

56

3772

0.125

3.5

440

450

3×300 + 2×150

1.8

3

64.6

4673

0.1

3.5

505

515

Kabel Daya Aluminium 4+1 inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

4×6 + 1×4

0.7

1.8

15

259

4.61

3.5

43

57

4×10 + 1×6

0.7

1.8

17.7

364

3.08

3.5

60

77

4×16 + 1×10

0.7

1.8

20.3

490

1.91

3.5

83

105

4×25 + 1×16

0.9

1.8

24.2

665

1.2

3.5

105

125

4×35 + 1×16

0.9

1.8

26.4

803

0.868

3.5

125

155

4×50 + 1×25

1

1.9

32.6

1114

0.641

3.5

160

185

4×70 + 1×35

1.1

2.1

37.4

1806

0.443

3.5

200

225

4×95 + 1×50

1.1

2.2

42.4

2211

0.32

3.5

245

270

4×120 + 1×70

1.2

2.4

47.9

2677

0.253

3.5

285

310

4×150 + 1×70

1.4

2.5

51.9

3135

0.206

3.5

325

345

4×185 + 1×95

1.6

2.7

58

4038

0.164

3.5

375

390

4×240 + 1×120

1.7

2.9

65.1

4919

0.125

3.5

440

450

4×300 + 1×150

1.8

3.1

72

5957

0.1

3.5

505

515

包装与运输Nalika nggunakake filosofi perusahaan "Berorientasi Klien", metode manajemen kualitas dhuwur sing nuntut, produk prodhuksi inovatif lan uga tenaga kerja R&D sing kuat, kita mesthi ngirim barang dagangan kualitas premium, solusi sing paling apik lan rega adol agresif kanggo Tegangan Rendah 0.6 / 1kv kualitas apik. Underground Copper / Aluminium Conductor XLPE Insulated PVC Sheathed Steel Wire Armored Power Cable, Perusahaan kita seneng banget karo kanca-kanca saka sak ndonya kanggo ngunjungi, neliti lan negosiasi bisnis.
Kualitas apikKabel China lan Kabel Listrik, Nyedhiyakake produk lan solusi sing paling apik, layanan sing paling sampurna kanthi rega sing paling terjangkau yaiku prinsip kita.Kita uga nampa pesenan OEM lan ODM. Dedicated kanggo kontrol kualitas sing ketat lan layanan pelanggan sing wicaksana, kita tansah kasedhiya kanggo ngrembug syarat sampeyan lan njamin kepuasan pelanggan lengkap.We Sincerely welcome kanca teka rembugan bisnis lan miwiti kerjasama.


  • Sadurunge:
  • Sabanjure:

  • Tulis pesen ing kene lan kirim menyang kita