8.7 / 15kv CU / XLPE / PVC Kabel Daya Tegangan Sedheng
Aplikasi
Kabel kasebut dirancang kanggo distribusi daya listrik kanthi voltase nominal Uo / U wiwit saka 3.6 / 6.6KV nganti 19 / 33KV lan frekuensi 50Hz.Padha cocok kanggo instalasi biasane ing stasiun sumber daya, ing jero ruangan lan ing saluran kabel, njobo, lemah lan ing banyu uga kanggo instalasi ing tray kabel kanggo industri, switchboards lan stasiun daya.
Konstruksi
Karakteristik
voltase dirating | 8,7 / 15 kV |
Konduktor | Tembaga Murni |
Isolasi | XLPE |
Sarung | PVC |
Suhu operasi | nganti 90 ° C |
Suhu Short Circuit | 250°C |
Radius mlengkung | 15 x OD |
Standar
GB/T 12706, IEC, BS, DIN lan ICEA miturut panyuwunan
Paramèter
1 Kabel Daya Volt Sedheng inti | ||||||||
Nom.Cross-bagean saka konduktor | Ketebalan Isolasi | Ketebalan Sarung | Kira-kira.OD | Kira-kira Bobot | Maks.Resistansi DC Konduktor (20°C) | Tes Tegangan AC | Rating saiki | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV / 5 min | Ing udara (A) | Ing lemah (A) |
1×25 | 4.5 | 1.8 | 23 | 680 | 0.727 | 30.5 | 140 | 150 |
1×35 | 4.5 | 1.8 | 24 | 804 | 0.524 | 30.5 | 175 | 180 |
1×50 | 4.5 | 1.9 | 25 | 984 | 0.387 | 30.5 | 205 | 215 |
1×70 | 4.5 | 1.9 | 27 | 1201 | 0.268 | 30.5 | 260 | 265 |
1×95 | 4.5 | 2 | 29 | 1490 | 0.193 | 30.5 | 315 | 315 |
1×120 | 4.5 | 2 | 30 | 1765 | 0.153 | 30.5 | 365 | 360 |
1×150 | 4.5 | 2.1 | 32 | 2091 | 0.124 | 30.5 | 415 | 405 |
1×185 | 4.5 | 2.1 | 34 | 2452 | 0,0991 | 30.5 | 475 | 455 |
1×240 | 4.5 | 2.2 | 36 | 3034 | 0,0754 | 30.5 | 565 | 530 |
1×300 | 4.5 | 2.4 | 39 | 3672 | 0,0601 | 30.5 | 645 | 595 |
1×400 | 4.5 | 2.4 | 42 | 4646 | 0.047 | 30.5 | 750 | 680 |
1×500 | 4.5 | 2.5 | 45 | 5651 | 0,0366 | 30.5 | 865 | 765 |
1×630 | 4.5 | 2.5 | 50 | 7154 | 0,0283 | 30.5 | 990 | 860 |
1×800 | 4.5 | 2.7 | 55 | 8750 | 0,0221 | 30.5 | 1140 | 950 |
1×1000 | 4.5 | 2.9 | 59 | 10727 | 0,0176 | 30.5 | 1250 | 1040 |
3 Kabel Daya Volt Sedheng inti | ||||||||
Nom.Cross-bagean saka konduktor | Ketebalan Isolasi | Ketebalan Sarung | Kira-kira.OD | Kira-kira Bobot | Maks.Resistansi DC Konduktor (20°C) | Tes Tegangan AC | Rating saiki | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV / 5 min | Ing udara (A) | Ing lemah (A) |
3×25 | 4.5 | 2.4 | 46 | 2573 | 0.727 | 30.5 | 120 | 125 |
3×35 | 4.5 | 2.6 | 48 | 2985 | 0.524 | 30.5 | 145 | 155 |
3×50 | 4.5 | 2.7 | 51 | 3529 | 0.387 | 30.5 | 175 | 180 |
3×70 | 4.5 | 2.8 | 55 | 4197 | 0.268 | 30.5 | 220 | 220 |
3×95 | 4.5 | 2.9 | 58 | 5230 | 0.193 | 30.5 | 265 | 265 |
3×120 | 4.5 | 3 | 61 | 6120 | 0.153 | 30.5 | 305 | 300 |
3×150 | 4.5 | 3.1 | 64 | 7207 | 0.124 | 30.5 | 350 | 340 |
3×185 | 4.5 | 3.2 | 68 | 8378 | 0,0991 | 30.5 | 395 | 380 |
3×240 | 4.5 | 3.4 | 73 | 10177 | 0,0754 | 30.5 | 470 | 435 |
3×300 | 4.5 | 3.5 | 77 | 12159 | 0,0601 | 30.5 | 535 | 485 |
3×400 | 4.5 | 3.8 | 86 | 15641 | 0.047 | 30.5 | 610 | 520 |
FAQ
P: Apa kita bisa duwe logo utawa jeneng perusahaan sing bakal dicithak ing produk utawa paket sampeyan?
A: Urutan OEM & ODM disambut kanthi apik lan kita duwe pengalaman sukses ing proyek OEM.Apa maneh, tim R&D kita bakal menehi saran profesional.
Q: Apa syarat pembayaran?
A: 30% T / T simpenan, 70% T / T imbangan pembayaran sadurunge pangiriman.
P: Kepiye pabrik sampeyan nindakake babagan kontrol kualitas?
A: Kita duwe sistem kontrol kualitas sing ketat, lan ahli profesional bakal mriksa tampilan lan fungsi tes kabeh barang sadurunge dikirim.
Q: Kepiye carane bisa njaluk sampel kanggo nguji kualitas sampeyan?
A: Kita bisa nyedhiyakake conto gratis kanggo tes lan mriksa, mung kudu nanggung biaya pengiriman.