2019 China Desain Baru 0.6/1kv Yjv Yjv22 23 XLPE Kabel PVC Insulated Armored Kabel Daya Fleksibel

Katrangan singkat:

Kabel digunakake kanggo sumber listrik ing sistem instalasi voltase kurang, Padha cocok kanggo instalasi ing njero ruangan lan njobo, ing saluran kabel, ing lemah, ing daya lan ngoper stasiun, distribusi energi lokal, tanduran industri, ngendi ora ana risiko mechanical. karusakan.

 

 

Penerimaan: OEM/ODM, Perdagangan, Grosir, Agensi Regional

Pembayaran: T/T, L/C, PayPal

Sampel Saham Gratis & Kasedhiya


Detail Produk

Tag produk

Bebarengan karo filosofi perusahaan "Berorientasi Klien", program pangaturan kualitas sing ketat, peralatan produksi sing canggih lan staf R&D sing solid, kita terus-terusan ngirim solusi kualitas premium, produk lan layanan sing paling apik lan kisaran rega sing agresif kanggo 2019 China New Design 0.6/ 1kv Yjv Yjv22 23 XLPE Kabel PVC Insulated Armored Fleksibel Power Cable, piranti proses Akurat, Advanced Injection Molding Equipment, Equipment line perakitan, labs lan software advancement kita fitur mbedakake.
Bebarengan karo filosofi perusahaan "Berorientasi Klien", program regulasi kualitas dhuwur sing ketat, peralatan produksi sing canggih lan staf R&D sing solid, kita terus-terusan ngirim solusi kualitas premium, produk lan layanan sing apik lan kisaran rega sing agresif kanggoChina 0.6/1kv lan Yjv Yjv22 23, Yen sampeyan butuh barang dagangan, utawa duwe barang liyane sing bakal diprodhuksi, elinga ngirim pitakon, conto utawa gambar lengkap.Kangge, ngarahake kanggo berkembang dadi klompok perusahaan internasional, kita ngarep-arep kanggo nampa tawaran kanggo joint ventures lan proyèk koperasi liyane.

Aplikasi

Trunking kabel njero ruangan, njaba kanggo stasiun listrik, industri lan switchgear uga kanggo jaringan pasokan kutha, yen karusakan mekanis ora mungkin.

Konstruksi

avava

Karakteristik

Dirating voltase: 0.6/1kV

1. sak operasi normal kabel, suhu konduktor maksimum kudu 70 ℃ kanggo PVC jampel lan 90 ℃ kanggo XLPE jampel.
2. Suhu maksimum konduktor sajrone sirkuit cendhak (durasi maksimal ora ngluwihi 5 detik): Insulasi PVC - 160 ℃ kanggo bagean konduktor ≤300mm2, 140 ℃ kanggo bagean salib konduktor> 300mm2;Crosslinked PVC insulasi ing 250 ℃.
3. Nalika mbikak kabel, suhu sekitar ora bakal kurang saka 0 ℃, lan minimal allowable mlengkung radius minangka nderek:
Kabel inti tunggal: 20D tanpa lapis baja, 15D lapis baja
Kabel multi-inti: 15D kanggo unarmored, 12D kanggo armored
Where: D- diameteripun njaba kabel.
4. Kabel putus gaya:
Kabel inti aluminium: 40 × S (N)
Kabel inti tembaga: 70 × S (N)
Cathetan: S yaiku total area cross-sectional konduktor

Standar

IEC 60502-1, GB/T 12706.1

Paramèter

Kabel Daya Inti Tunggal

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

1×1.5

0.7

1.4

6

53

12.1

3.5

22

33

1×2.5

0.7

1.4

6

68

7.41

3.5

31

43

1×4

0.7

1.4

7

87

4.61

3.5

41

56

1×6

0.7

1.4

7

110

3.08

3.5

52

70

1×10

0.7

1.4

8

155

1.83

3.5

71

94

1×16

0.7

1.4

9

220

1.15

3.5

92

120

1×25

0.9

1.4

10

345

0.727

3.5

120

155

1×35

0.9

1.4

12

424

0.524

3.5

150

185

1×50

1

1.4

13

555

0.387

3.5

180

220

1×70

1.1

1.4

14

770

0.268

3.5

230

270

1×95

1.1

1.5

16

1040

0.193

3.5

285

320

1×120

1.2

1.5

18

1290

0.153

3.5

335

365

1×150

1.4

1.6

20

1590

0.124

3.5

385

410

1×185

1.6

1.6

22

1944

0,0991

3.5

450

465

1×240

1.7

1.7

25

2510

0,0754

3.5

535

540

1×300

1.8

1.8

27

3042

0,0601

3.5

620

610

1×400

2

1.9

31

3869

0.047

3.5

720

695

1×500

2.2

2.1

35

4910

0,0366

3.5

835

780

1×630

2.4

2.2

40

6220

0,0283

3.5

960

880

1×800

2.6

2.4

45

7870

0,0221

3.5

1110

970

1×1000

2.8

2.6

51

9804

0,0176

3.5

1230

1060

2 Kabel Daya Inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

2×2.5

0.7

1.8

11.8

151

7.41

3.5

26

35

2×4

0.7

1.8

12.7

198

4.61

3.5

34

45

2×6

0.7

1.8

13.7

250

3.08

3.5

43

57

2×10

0.7

1.8

15

374

1.83

3.5

60

77

2×16

0.7

1.8

17

518

1.15

3.5

83

105

2×25

0.9

1.8

20

772

0.727

3.5

105

125

2×35

0.9

1.8

22

1006

0.524

3.5

125

155

2×50

1

1.8

20

1365

0.387

3.5

160

185

2×70

1.1

1.8

21

1872

0.268

3.5

200

225

2×95

1.1

1.8

24

2475

0.193

3.5

245

270

2×120

1.2

1.8

27

3089

0.153

3.5

285

310

2×150

1.4

1.9

30

3834

0.124

3.5

325

345

3 Kabel Daya Inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

3×1.5

0.7

1.5

10

145

12.1

3.5

20

27

3×2.5

0.7

1.5

11

185

7.41

3.5

26

35

3×4

0.7

1.5

12

250

4.61

3.5

34

45

3×6

0.7

1.5

13

320

3.08

3.5

43

57

3×10

0.7

1.8

16

450

1.83

3.5

60

77

3×16

0.7

1.8

18

640

1.15

3.5

83

105

3×25

0.9

1.8

21

940

0.727

3.5

105

125

3×35

0.9

1.8

23

1260

0.524

3.5

125

155

3×50

1

1.8

23

1670

0.387

3.5

160

185

3×70

1.1

1.8

26

2280

0.268

3.5

200

225

3×95

1.1

1.9

30

3020

0.193

3.5

245

270

3×120

1.2

2

32

3790

0.153

3.5

285

310

3×150

1.4

2.2

37

4750

0.124

3.5

325

345

3×185

1.6

2.3

41

5654

0,0991

3.5

375

390

3×240

1.7

2.4

46

7243

0,0754

3.5

440

450

3×300

1.8

2.6

51

9465

0,0601

3.5

505

515

3×400

2

3

64

12066

0.047

3.5

570

575

4 Kabel Daya Inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

4×4

0.7

1.8

13

253

4.61

3.5

34

45

4×6

0.7

1.8

14

337

3.08

3.5

43

57

4×10

0.7

1.8

17

501

1.83

3.5

60

77

4×16

0.7

1.8

20

778

1.15

3.5

83

105

4×25

0.9

1.8

23

1160

0.727

3.5

105

125

4×35

0.9

1.8

25

1554

0.524

3.5

125

155

4×50

1

1.8

23

2148

0.387

3.5

160

185

4×70

1.1

1.8

27

2928

0.268

3.5

200

225

4×95

1.1

1.9

31

3854

0.193

3.5

245

270

4×120

1.2

2

33

4925

0.153

3.5

285

310

4×150

1.4

2.2

38

6238

0.124

3.5

325

345

4×185

1.6

2.3

42

7562

0,0991

3.5

375

390

4×240

1.7

2.5

47

9836

0,0754

3.5

440

450

4×300

1.8

2.6

52

12550

0,0601

3.5

505

515

4×400

2

3.1

66

15929

0.047

3.5

570

575

5 Kabel Daya Inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

5×4

0.7

1.8

14.5

349

4.61

3.5

34

45

5×6

0.7

1.8

15.8

460

3.08

3.5

43

57

5×10

0.7

1.8

19

699

1.83

3.5

60

77

5×16

0.7

1.8

22

1013

1.15

3.5

83

105

5×25

0.9

1.8

25

1566

0.727

3.5

105

125

5×35

0.9

1.9

28

2083

0.524

3.5

125

155

5×50

1

2

31

2921

0.387

3.5

160

185

5×70

1.1

2.1

36

3974

0.268

3.5

200

225

5×95

1.1

2.2

39

5297

0.193

3.5

245

270

5×120

1.2

2.4

44

6638

0.153

3.5

285

310

5×150

1.4

2.5

49

8290

0.124

3.5

325

345

5×185

1.6

2.7

55

10215

0,0991

3.5

375

390

5×240

1.7

3

64

13130

0,0754

3.5

440

450

5×300

1.8

3.2

70

16670

0,0601

3.5

505

515

Kabel Daya 3+1 inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

3×4+1×2.5

0.7

1.8

13

236

4.61

3.5

34

45

3×6+1×4

0.7

1.8

14

316

3.08

3.5

43

57

3×10+1×6

0.7

1.8

17

461

1.83

3.5

60

77

3×16+1×10

0.7

1.8

19

679

1.15

3.5

83

105

3×25+1×16

0.9

1.8

22

1065

0.727

3.5

105

125

3×35+1×16

0.9

1.8

24

1360

0.524

3.5

125

155

3×50+1×25

1

1.8

25

1901

0.387

3.5

160

185

3×70+1×35

1.1

1.9

28

2585

0.268

3.5

200

225

3×95+1×50

1.1

2

32

3518

0.193

3.5

245

270

3×120+1×70

1.2

2.1

35

4443

0.153

3.5

285

310

3×150+1×70

1.4

2.2

40

5326

0.124

3.5

325

345

3×185+1×95

1.6

2.4

43

8501

0,0991

3.5

375

390

3×240+1×120

1.7

2.5

48

11155

0,0754

3.5

440

450

3×300+1×150

1.8

2.7

54

14470

0,0601

3.5

505

515

3×400+1×240

2

3.1

66

309

0.047

3.5

570

575

Kabel Daya 3+2 inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

3×4+2×2.5

0.7

1.8

13.9

413

4.61

3.5

34

45

3×6+2×4

0.7

1.8

15.3

6682

3.08

3.5

43

57

3×10+2×6

0.7

1.8

18

603

1.83

3.5

60

77

3×16+2×10

0.7

1.8

21

888

1.15

3.5

83

105

3×25+2×16

0.9

1.8

24

1342

0.727

3.5

105

125

3×35+2×16

0.9

1.8

26

1647

0.524

3.5

125

155

3×50+2×35

1

1.9

29

2386

0.387

3.5

160

185

3×70+2×35

1.1

2

32

3201

0.268

3.5

200

225

3×95+2×50

1.1

2.1

36

4269

0.193

3.5

245

270

3×120+2×70

1.2

2.3

41

5437

0.153

3.5

285

310

3×150+2×70

1.4

2.4

44

6519

0.124

3.5

325

345

3×185+2×95

1.6

2.5

49

8101

0,0991

3.5

375

390

3×240+2×120

1.7

2.7

54

10340

0,0754

3.5

440

450

3×300+2×150

1.8

2.8

56

12810

0,0601

3.5

505

515

Kabel Daya 4+1 inti

Nom.Cross-bagean saka konduktor

Ketebalan Isolasi

Ketebalan Sarung

Kira-kira.OD

Kira-kira Bobot

Maks.Resistansi DC Konduktor (20°C)

Tes Tegangan AC

Rating saiki

mm2

mm

mm

mm

kg/km

Ω/km

kV / 5 min

Ing udara (A)

Ing lemah (A)

4×4+1×2.5

0.7

1.8

14.5

331

4.61

3.5

34

45

4×6+1×4

0.7

1.8

15.9

435

3.08

3.5

43

57

4×10+1×6

0.7

1.8

18

649

1.83

3.5

60

77

4×16+1×10

0.7

1.8

21

965

1.15

3.5

83

105

4×25+1×16

0.9

1.8

25

1456

0.727

3.5

105

125

4×35+1×16

0.9

1.8

27

1863

0.524

3.5

125

155

4×50+1×25

1

1.9

29

2633

0.387

3.5

160

185

4×70+1×35

1.1

2

32

3565

0.268

3.5

200

225

4×95+1×50

1.1

2.1

36

4735

0.193

3.5

245

270

4×120+1×70

1.2

2.3

41

5977

0.153

3.5

285

310

4×150+1×70

1.4

2.4

44

7276

0.124

3.5

325

345

4×185+1×95

1.6

2.5

49

9055

0,0991

3.5

375

390

4×240+1×120

1.7

2.7

54

11567

0,0754

3.5

440

450

4×300+1×150

1.8

3.1

66

14321

0,0601

3.5

505

515

包装与运输Bebarengan karo filosofi perusahaan "Berorientasi Klien", program pangaturan kualitas sing ketat, peralatan produksi sing canggih lan staf R&D sing solid, kita terus-terusan ngirim solusi kualitas premium, produk lan layanan sing paling apik lan kisaran rega sing agresif kanggo 2019 China New Design 0.6/ 1kv Yjv Yjv22 23 XLPE Kabel PVC Insulated Armored Fleksibel Power Cable, piranti proses Akurat, Advanced Injection Molding Equipment, Equipment line perakitan, labs lan software advancement kita fitur mbedakake.
2019 Desain Anyar ChinaChina 0.6/1kv lan Yjv Yjv22 23, Yen sampeyan butuh barang dagangan, utawa duwe barang liyane sing bakal diprodhuksi, elinga ngirim pitakon, conto utawa gambar lengkap.Kangge, ngarahake kanggo berkembang dadi klompok perusahaan internasional, kita ngarep-arep kanggo nampa tawaran kanggo joint ventures lan proyèk koperasi liyane.


  • Sadurunge:
  • Sabanjure:

  • Tulis pesen ing kene lan kirim menyang kita