0.6/1kv AL/XLPE/PVC Aluminium Kabel Daya
Aplikasi
0.6/1kv Xlpe terisolasi Pvc kabel daya aluminium sheathed digunakake kanggo distribusi daya ing pembangkit listrik, instalasi industri lan switchgears, uga ing utama lokal.Bisa nanggung traksi tartamtu sajrone instalasi.Kanggo instalasi tetep ing lemah.
Konstruksi
Karakteristik
voltase dirating | 0,6/1 kV |
Konduktor | alumunium |
Isolasi | XLPE |
Sarung | PVC |
inti | 1, 2, 3, 4, 5, 3+1, 3+2, 4+1 |
warna | Black utawa Customized |
Standar
GB/T 12706, IEC, BS, DIN lan ICEA miturut panyuwunan
Paramèter
Kabel Daya Aluminium 2 inti | ||||||||
Nom.Cross-bagean saka konduktor | Ketebalan Isolasi | Ketebalan Sarung | Kira-kira.OD | Kira-kira Bobot | Maks.Resistansi DC Konduktor (20°C) | Tes Tegangan AC | Rating saiki | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV / 5 min | Ing udara (A) | Ing lemah (A) |
2x4 | 0.7 | 1.8 | 11.4 | 150 | 7.41 | 3.5 | 34 | 45 |
2×6 | 0.7 | 1.8 | 12.4 | 171 | 4.61 | 3.5 | 43 | 57 |
2×10 | 0.7 | 1.8 | 14.9 | 238 | 3.08 | 3.5 | 60 | 77 |
2×16 | 0.7 | 1.8 | 17.1 | 294 | 1.91 | 3.5 | 83 | 105 |
2×25 | 0.9 | 1.8 | 20 | 394 | 1.2 | 3.5 | 105 | 125 |
2×35 | 0.9 | 1.8 | 22 | 484 | 0.868 | 3.5 | 125 | 155 |
2×50 | 1 | 1.8 | 23.4 | 497 | 0.641 | 3.5 | 160 | 185 |
2×70 | 1.1 | 1.8 | 24.5 | 640 | 0.443 | 3.5 | 200 | 225 |
2×95 | 1.1 | 1.9 | 28.6 | 827 | 0.32 | 3.5 | 245 | 270 |
2×120 | 1.2 | 2 | 29.7 | 1015 | 0.253 | 3.5 | 285 | 310 |
2×150 | 1.4 | 2.2 | 31.2 | 1268 | 0.206 | 3.5 | 325 | 345 |
Kabel Daya Aluminium 3 Inti | ||||||||
Nom.Cross-bagean saka konduktor | Ketebalan Isolasi | Ketebalan Sarung | Kira-kira.OD | Kira-kira Bobot | Maks.Resistansi DC Konduktor (20°C) | Tes Tegangan AC | Rating saiki | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV / 5 min | Ing udara (A) | Ing lemah (A) |
3×4 | 0.7 | 1.8 | 12 | 163 | 7.41 | 3.5 | 34 | 45 |
3×6 | 0.7 | 1.8 | 13 | 191 | 4.61 | 3.5 | 43 | 57 |
3×10 | 0.7 | 1.8 | 15.8 | 282 | 3.08 | 3.5 | 60 | 77 |
3×16 | 0.7 | 1.8 | 18.2 | 358 | 1.91 | 3.5 | 83 | 105 |
3×25 | 0.9 | 1.8 | 21.3 | 491 | 1.2 | 3.5 | 105 | 125 |
3×35 | 0.9 | 1.8 | 23.6 | 600 | 0.868 | 3.5 | 125 | 155 |
3×50 | 1 | 1.8 | 23.8 | 729 | 0.641 | 3.5 | 160 | 185 |
3×70 | 1.1 | 1.9 | 27.4 | 958 | 0.443 | 3.5 | 200 | 225 |
3×95 | 1.1 | 2 | 33.1 | 1242 | 0.32 | 3.5 | 245 | 270 |
3×120 | 1.2 | 2.1 | 34.7 | 1502 | 0.253 | 3.5 | 285 | 310 |
3×150 | 1.4 | 2.3 | 39.1 | 1875 | 0.206 | 3.5 | 325 | 345 |
3×185 | 1.6 | 2.4 | 42.3 | 2264 | 0.164 | 3.5 | 375 | 390 |
3×240 | 1.7 | 2.6 | 47.8 | 2861 | 0.125 | 3.5 | 440 | 450 |
3×300 | 1.8 | 2.8 | 52.4 | 3501 | 0.1 | 3.5 | 505 | 515 |
3×400 | 2 | 3.1 | 62.9 | 4627 | 0,0778 | 3.5 | 570 | 575 |
Kabel Daya Aluminium 4 Inti | ||||||||
Nom.Cross-bagean saka konduktor | Ketebalan Isolasi | Ketebalan Sarung | Kira-kira.OD | Kira-kira Bobot | Maks.Resistansi DC Konduktor (20°C) | Tes Tegangan AC | Rating saiki | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV / 5 min | Ing udara (A) | Ing lemah (A) |
4×4 | 0.7 | 1.8 | 13 | 197 | 7.41 | 3.5 | 34 | 45 |
4×6 | 0.7 | 1.8 | 14.2 | 233 | 4.61 | 3.5 | 43 | 57 |
4×10 | 0.7 | 1.8 | 17.2 | 345 | 3.08 | 3.5 | 60 | 77 |
4×16 | 0.7 | 1.8 | 19.9 | 442 | 1.91 | 3.5 | 83 | 105 |
4×25 | 0.9 | 1.8 | 23.4 | 595 | 1.2 | 3.5 | 105 | 125 |
4×35 | 0.9 | 1.8 | 25.8 | 734 | 0.868 | 3.5 | 125 | 155 |
4×50 | 1 | 1.9 | 27.2 | 912 | 0.641 | 3.5 | 160 | 185 |
4×70 | 1.1 | 2 | 27.9 | 1207 | 0.443 | 3.5 | 200 | 225 |
4×95 | 1.1 | 2.1 | 33.8 | 1569 | 0.32 | 3.5 | 245 | 270 |
4×120 | 1.2 | 2.3 | 35.8 | 1923 | 0.253 | 3.5 | 285 | 310 |
4×150 | 1.4 | 2.4 | 40.2 | 2374 | 0.206 | 3.5 | 325 | 345 |
4×185 | 1.6 | 2.6 | 43.6 | 2899 | 0.164 | 3.5 | 375 | 390 |
4×240 | 1.7 | 2.8 | 49.3 | 3670 | 0.125 | 3.5 | 440 | 450 |
4×300 | 1.8 | 3 | 54.1 | 4499 | 0.1 | 3.5 | 505 | 515 |
4×400 | 2 | 3.3 | 65.1 | 5947 | 0,0778 | 3.5 | 570 | 575 |
Kabel Daya Aluminium 5 Inti | ||||||||
Nom.Cross-bagean saka konduktor | Ketebalan Isolasi | Ketebalan Sarung | Kira-kira.OD | Kira-kira Bobot | Maks.Resistansi DC Konduktor (20°C) | Tes Tegangan AC | Rating saiki | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV / 5 min | Ing udara (A) | Ing lemah (A) |
5×4 | 0.7 | 1.8 | 14 | 223 | 7.41 | 3.5 | 34 | 45 |
5×6 | 0.7 | 1.8 | 15.3 | 266 | 4.61 | 3.5 | 43 | 57 |
5×10 | 0.7 | 1.8 | 18.7 | 395 | 3.08 | 3.5 | 60 | 77 |
5×16 | 0.7 | 1.8 | 21.7 | 512 | 1.91 | 3.5 | 83 | 105 |
5×25 | 0.9 | 1.8 | 25.6 | 700 | 1.2 | 3.5 | 105 | 125 |
5×35 | 0.9 | 1.8 | 28.3 | 872 | 0.868 | 3.5 | 125 | 155 |
5×50 | 1 | 2 | 31.6 | 1155 | 0.641 | 3.5 | 160 | 185 |
5×70 | 1.1 | 2.1 | 37.2 | 1536 | 0.443 | 3.5 | 200 | 225 |
5×95 | 1.1 | 2.3 | 41 | 1971 | 0.32 | 3.5 | 245 | 270 |
5×120 | 1.2 | 2.4 | 46.2 | 2430 | 0.253 | 3.5 | 285 | 310 |
5×150 | 1.4 | 2.6 | 50.8 | 3036 | 0.206 | 3.5 | 325 | 345 |
5×185 | 1.6 | 2.8 | 56.6 | 3716 | 0.164 | 3.5 | 375 | 390 |
5×240 | 1.7 | 3 | 62.8 | 4677 | 0.125 | 3.5 | 440 | 450 |
5×300 | 1.8 | 3.2 | 71.4 | 5758 | 0.1 | 3.5 | 505 | 515 |
Kabel Daya Aluminium 3+1 inti | ||||||||
Nom.Cross-bagean saka konduktor | Ketebalan Isolasi | Ketebalan Sarung | Kira-kira.OD | Kira-kira Bobot | Maks.Resistansi DC Konduktor (20°C) | Tes Tegangan AC | Rating saiki | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV / 5 min | Ing udara (A) | Ing lemah (A) |
3×4 + 1×2,5 | 0.7 | 1.8 | 12.7 | 189 | 7.41 | 3.5 | 34 | 45 |
3×6 + 1×4 | 0.7 | 1.8 | 13.9 | 224 | 4.61 | 3.5 | 43 | 57 |
3×10 + 1×6 | 0.7 | 1.8 | 16.4 | 311 | 3.08 | 3.5 | 60 | 77 |
3×16 + 1×10 | 0.7 | 1.8 | 19.2 | 418 | 1.91 | 3.5 | 83 | 105 |
3×25 + 1×16 | 0.9 | 1.8 | 22.5 | 557 | 1.2 | 3.5 | 105 | 125 |
3×35 + 1×16 | 0.9 | 1.8 | 25 | 667 | 0.868 | 3.5 | 125 | 155 |
3×50 + 1×25 | 1 | 1.8 | 25.5 | 833 | 0.641 | 3.5 | 160 | 185 |
3×70 + 1×35 | 1.1 | 1.9 | 28.9 | 1096 | 0.443 | 3.5 | 200 | 225 |
3×95 + 1×50 | 1.1 | 2.1 | 35.3 | 1448 | 0.32 | 3.5 | 245 | 270 |
3×120 + 1×70 | 1.2 | 2.2 | 37.1 | 1787 | 0.253 | 3.5 | 285 | 310 |
3×150 + 1×70 | 1.4 | 2.3 | 41.7 | 2143 | 0.206 | 3.5 | 325 | 345 |
3×185 + 1×95 | 1.6 | 2.5 | 45.3 | 2629 | 0.164 | 3.5 | 375 | 390 |
3×240 + 1×120 | 1.7 | 2.7 | 51.3 | 3314 | 0.125 | 3.5 | 440 | 450 |
3×300 + 1×150 | 1.8 | 2.9 | 56.3 | 4062 | 0.1 | 3.5 | 505 | 515 |
3×400 + 1×240 | 2 | 3.1 | 67.6 | 5295 | 0,0778 | 3.5 | 570 | 575 |
Kabel Daya Aluminium 3+2 inti | ||||||||
Nom.Cross-bagean saka konduktor | Ketebalan Isolasi | Ketebalan Sarung | Kira-kira.OD | Kira-kira Bobot | Maks.Resistansi DC Konduktor (20°C) | Tes Tegangan AC | Rating saiki | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV / 5 min | Ing udara (A) | Ing lemah (A) |
3×4 + 2×2,5 | 0.7 | 1.8 | 13.5 | 208 | 7.41 | 3.5 | 34 | 45 |
3×6 + 2×4 | 0.7 | 1.8 | 14.8 | 249 | 4.61 | 3.5 | 43 | 57 |
3×10 + 2×6 | 0.7 | 1.8 | 17.4 | 343 | 3.08 | 3.5 | 60 | 77 |
3×16 + 2×10 | 0.7 | 1.8 | 20.5 | 465 | 1.91 | 3.5 | 83 | 105 |
3×25 + 2×16 | 0.9 | 1.8 | 24 | 625 | 1.2 | 3.5 | 105 | 125 |
3×35 + 2×16 | 0.9 | 1.8 | 25.7 | 728 | 0.868 | 3.5 | 125 | 155 |
3×50 + 2×35 | 1 | 1.9 | 29 | 980 | 0.641 | 3.5 | 160 | 185 |
3×70 + 2×35 | 1.1 | 2 | 33.8 | 1284 | 0.443 | 3.5 | 200 | 225 |
3×95 + 2×50 | 1.1 | 2.2 | 37.4 | 1660 | 0.32 | 3.5 | 245 | 270 |
3×120 + 2×70 | 1.2 | 2.3 | 42.8 | 2089 | 0.253 | 3.5 | 285 | 310 |
3×150 + 2×70 | 1.4 | 2.4 | 45.2 | 2424 | 0.206 | 3.5 | 325 | 345 |
3×185 + 2×95 | 1.6 | 2.6 | 50.6 | 3010 | 0.164 | 3.5 | 375 | 390 |
3×240 + 2×120 | 1.7 | 2.8 | 56 | 3772 | 0.125 | 3.5 | 440 | 450 |
3×300 + 2×150 | 1.8 | 3 | 64.6 | 4673 | 0.1 | 3.5 | 505 | 515 |
Kabel Daya Aluminium 4+1 inti | ||||||||
Nom.Cross-bagean saka konduktor | Ketebalan Isolasi | Ketebalan Sarung | Kira-kira.OD | Kira-kira Bobot | Maks.Resistansi DC Konduktor (20°C) | Tes Tegangan AC | Rating saiki | |
mm2 | mm | mm | mm | kg/km | Ω/km | kV / 5 min | Ing udara (A) | Ing lemah (A) |
4×6 + 1×4 | 0.7 | 1.8 | 15 | 259 | 4.61 | 3.5 | 43 | 57 |
4×10 + 1×6 | 0.7 | 1.8 | 17.7 | 364 | 3.08 | 3.5 | 60 | 77 |
4×16 + 1×10 | 0.7 | 1.8 | 20.3 | 490 | 1.91 | 3.5 | 83 | 105 |
4×25 + 1×16 | 0.9 | 1.8 | 24.2 | 665 | 1.2 | 3.5 | 105 | 125 |
4×35 + 1×16 | 0.9 | 1.8 | 26.4 | 803 | 0.868 | 3.5 | 125 | 155 |
4×50 + 1×25 | 1 | 1.9 | 32.6 | 1114 | 0.641 | 3.5 | 160 | 185 |
4×70 + 1×35 | 1.1 | 2.1 | 37.4 | 1806 | 0.443 | 3.5 | 200 | 225 |
4×95 + 1×50 | 1.1 | 2.2 | 42.4 | 2211 | 0.32 | 3.5 | 245 | 270 |
4×120 + 1×70 | 1.2 | 2.4 | 47.9 | 2677 | 0.253 | 3.5 | 285 | 310 |
4×150 + 1×70 | 1.4 | 2.5 | 51.9 | 3135 | 0.206 | 3.5 | 325 | 345 |
4×185 + 1×95 | 1.6 | 2.7 | 58 | 4038 | 0.164 | 3.5 | 375 | 390 |
4×240 + 1×120 | 1.7 | 2.9 | 65.1 | 4919 | 0.125 | 3.5 | 440 | 450 |
4×300 + 1×150 | 1.8 | 3.1 | 72 | 5957 | 0.1 | 3.5 | 505 | 515 |
FAQ
P: Apa kita bisa duwe logo utawa jeneng perusahaan sing bakal dicithak ing produk utawa paket sampeyan?
A: Urutan OEM & ODM disambut kanthi apik lan kita duwe pengalaman sukses ing proyek OEM.Apa maneh, tim R&D kita bakal menehi saran profesional.
Q: Apa syarat pembayaran?
A: 30% T / T simpenan, 70% T / T imbangan pembayaran sadurunge pangiriman.
P: Kepiye pabrik sampeyan nindakake babagan kontrol kualitas?
A: Kita duwe sistem kontrol kualitas sing ketat, lan ahli profesional bakal mriksa tampilan lan fungsi tes kabeh barang sadurunge dikirim.
Q: Kepiye carane bisa njaluk sampel kanggo nguji kualitas sampeyan?
A: Kita bisa nyedhiyakake conto gratis kanggo tes lan mriksa, mung kudu nanggung biaya pengiriman.